D&B D6 Spécifications

Naviguer en ligne ou télécharger Spécifications pour Amplificateurs audio D&B D6. D&B D6 Specifications [en] Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - Software manual (1.3 EN)

D6 AmplifierSoftware manual (1.3 EN)(Firmware V1.x.x)

Page 2

Speaker Q7CUT onHFA onCPL offFilter_1, Filter_2, Filter_3The name of the filter is display

Page 3 - Contents

Equalizer on SetSetSelecting "Set" enters the submenu and gives access to the four EQbands. Turning the encoder to right and pushing

Page 4 - 1. Introduction

LevelsCh A -3.0dB 36°CInput -80dBuHeadr. Z 255Power

Page 5 - 2. The D6 operating software

Channel NameEnables the assignment or editing of the channel name (maximum 15characters):1. Selecting "Channel Name" enters the submenu and

Page 6 - D6 Stage right

System CheckSystem CheckSystem Check is a powerful and convenient tool to check the conditionof either a single d&b loudspeaker or a complete d&am

Page 7 - D6 V X.xx

Calib. Load MonitoringCancelAPilot Signal LF + 0.0dBuCalib. Load MonitoringOkAFinished LF 9.1 HF 16.0ChkCal 0.0 -

Page 8 - Input digital

Load Monitoring ABackMode offDetection Time 99sDetection Time 1sDetection Time 99sLoad Monitoring menuModeSelecting "

Page 9

CalibrateNOTICE:Ensure that all components of the system are wired and workingcorrectly before executing the calibration!Selecting "Calibrate Now

Page 10 - CPL off

Link A B offLink A»BD6 Stage rightQ7 -3.0dB -3.0dBCUTHFAEQ0.01CSAEQQ-SUB +0.0dBL100LFig. 9: Link A»B indication on the MainscreenThe EQ a

Page 11 - G

Load Save Clear Ok!SelectTurning and pushing the encoder provides access to the nine user presetmemories to be loaded, saved or cleared.To r

Page 12 - Input :

General InformationD6 AmplifierSoftware manual (Firmware V1.x.x) Version 1.3 EN, 01/2013, D2018.EN .01Copyright © 2013 by d&b audiotechnik GmbH;

Page 13

Remote offRemoteFig. 10: Remote menuAll functions of the D6 can be remotely interrogated via the dbCAN(CAN-Bus).The menu header contain

Page 14 - LF .

Edit PasswordDBAUDIO Ok CancelEdit PasswordEnables the input of a new password or editing of an existing password(maximum 7 c

Page 15 - + 0.0dBu

OptionsBackDevice Name DisplayDevice NameEnables the assignment or editing of a device name (maximum 15characters):Single characters can be kept by si

Page 16 - Calibrate Now

InformationInformationSelecting "Information" and pressing the encoder enters the submenu.InformationBackTemp.Amp. 35°C 38°CTemp.PS.

Page 17 - Load Monitoring

PS LogPS LogSelecting "PS Log" (Power Supply Log) and pressing the encoderenters the submenu.Log Power SupplyBackPS Err 1xOvervolt.

Page 18 - AmpPreset 1

InpMonErrA numerical value indicating the number of times the D6 has enteredthe error condition "InpMonErr" due to an Input Monitoring fault

Page 19 - Load Save Clear Ok!

MUTE A/BNote:As the MUTE A/B switches isolate the D6 digital controller from thepower amplifiers the MUTE A/B switches do not affect the inputconnecto

Page 20 - Show Main Screen

Power SupplyPower SupplySelecting "Power Supply" and pressing the encoder enters the submenu.Power SupplyBackMains 230VFrequency 50HzM

Page 21

2.6 Display messages2.6.1 Error messagesError messages can be related either to the device ("Device") or to asingle or both channels of th

Page 22 - Device Name

Channel Amp. Overtemp. ([xx] °C): the temperature of the heat sink is toohigh and the device is muted and the loudspeaker output is switched off.After

Page 23 - Information

Contents1. Introduction...41.1 Block diagram of the DSP software...

Page 24 - Channel B

2.6.4 Further messagesThe following messages are intended for information on the status ofthe D6. They are no error messages.Standby: indicates that

Page 25

3. D6 Firmware updateNote:A firmware update erases all user settings of the device. The devicename and the log files are kept.The operating software –

Page 26 - Detected? yes - 42dBu

D2018.EN .01, 01/2013 © d&b audiotechnik GmbHd&b audiotechnik GmbH, Eugen-Adolff-Str. 134, D-71522 Backnang, Germany, Phone +49-7191-9669-0, F

Page 27 - Frequency 50Hz

1. IntroductionThis manual describes the structure, access (user interface) and functionsof the firmware of the d&b D6 amplifier. A detailed descr

Page 28

2. The D6 operating software2.1 Menu treeThe menu structure of Channel A is shown in detail. The same structureapplies to Channel B.The settings for

Page 29

2.2 User interfaceD6 Stage rightCUTHFAEQEQQ-SUBThe LCD [4] acts as a user interface for all of the menus within the D6.The cursor is controlled via t

Page 30 - Press A again to reboot

2.3 Boot screenD6 V X.xxD6d&baudiotechnikFig. 1: Boot screenThe boot procedure takes approximately 4 seconds during which thedevice name, the ma

Page 31 - 3. D6 Firmware update

2.5 Settings menuSettings Id0.01BackInput analogCh A Q7Ch B Q-SUB offRemote offLock Press 2sOptionsFig. 3: Setting

Page 32

Setup Channel ABackSource Input ASpeaker Q7Source Input A+BSetup Channel A (B)Source (Input routing)Within the submenus "

Commentaires sur ces manuels

Pas de commentaire